Royal Point
Other Brand Point
The cross-sectional area of the point on the Royal Center is 68% larger
than that of the other brand, making the Royal point much more rigid and
less likely to deflect under load.
Royal's thick, beefy point offers superior rigidity, resulting in tighter part
tolerances and chatter-free surface-finishes.
D1
D2
Point Analysis of 4MT Spindle Type Live Centers
D1 = Diameter of Royal Point = .603"
D2 = Diameter of Other Brand Point = .465"
Cross-Sectional Area of Royal Point = .285 sq. in.
Cross-Sectional Area of Other Brand Point = .170 sq. in.
One of the most common misconceptions regarding live centers
relates to the internal length of the rotating point.
Some manufacturers believe that a long, thin point provides more
rigidity than a short, thick point. But in fact, the opposite is true.
In order to verify that Royal’s short, thick point provides superior rigidity
over a long, thin point, we built the test fixture pictured above.
Here’s how it works:
Both live centers have holes drilled in their shanks corresponding
to the indicator locations.
As radial force is applied evenly to the point tips by turning a
centrally-located screw, the indicators are able to measure the
internal deflection of each point.
Almost immediately upon application of the load, the indicators
show that the competitor’s point flexes 600% more than the
Royal point!
Royal Center Competitor Center
Page view 61