Page 1 - Model 6130

SCALE MASTER®IIv3.0ADVANCED DIGITAL PLAN MEASUREModel 6130

Page 2 - TABLE OF CONTENTS

“Rolling” a MeasurementTo take a measurement with the ScaleMaster II:1) Switch the unit on. If the displaydoes not show zero (0), press the[Reset] key

Page 4 - Key Definitions

Built-In ScalesImperial (English) UnitsArchitect Engineer-I Engineer-II MapARCH ENGI ENGII MAP1 foot= 1 inch= 1 inch= 1 inch=1/32” 10.0’ 300.0’ 1.0 Mi

Page 5 - User’s Guide – 5

Metric UnitsArchitect Engineer-I Engineer-II MapARCH ENGI ENGII MAP1:1 1:100.0 1:1,000 1:100k1:2 1:125.0 1:1,250 1:125k1:3 1:150.0 1:1,500 1:200k1:4 1

Page 6 - 6 – Scale Master

You can also convert values fromImperial Units (English) to MetricUnits within the Imperial mode.B) Press [Set] [Mode] and continuepressing [Mode] to

Page 7 - [Set] will store the value as

Locking Scale SettingsYour Scale Master II comes equipped witha lock switch that prevents inadvertentlychanging drawing scales. When the lockis activa

Page 8 - Adjusting the Wheel

3) You can continue to add values us-ing the [M+] key. Press [Rcl] [M+] toreview the total in Memory.*Note: For count values, you must pressthe [Count

Page 9 - USING THE

Other Memory Function Keystrokes[Set] [M+]Replaces the contents of Memorywith the displayed value.[Set] then [Sub] and [M+] simultaneouslyReplaces the

Page 10 - “Rolling” a Measurement

Programming ModeThe Scale Master II allows you to pre-set values into frequently used keys,including: ◆ Custom Scales (4 Imp/4 Met)◆ Auto-Count distan

Page 11 - User’s Guide – 11

Setting Custom ScalesYou can program and store eight Cus-tom Scales: four in Imperial (English)and four in Metric Units. The defaultunits of measureme

Page 12 - Built-In Scales

Preliminary InformationIntroduction . . . . . . . . . . . . . . . . . . . .3Key Definitions . . . . . . . . . . . . . . . . .4Adjusting the Wheel .

Page 13 - Changing Measurement Units

4) Press [Scale]. The appropriate an-nunciator will begin flashing “FT-IN“ for Imperial Mode, “MM” forMetric Mode.5) If you want to change the units o

Page 14 - Converting Between Scales

Setting a Custom Scale1) Press [Mode] until 1:CUS_x (x beinga number 1-4) appears in the scalebox display. 2) Press [Set] [Scale]. “ROLL” will ap-pear

Page 15 - Using the Memory Function

the next digit. You can press the[Mode] key to move back one digit.6) Once the desired value has beenset, press [Set] to store the valueand exit the p

Page 16 - M” will display

Setting an Auto-Count ValueThe Scale Master II has an Auto-Countmode that allows you to count howmany times you’ve rolled a certain dis-tance. You wil

Page 17 - [Sub] and [M+] simultaneously

4) Press [Set] to save changes and putthe unit into auto-count measuringmode.5) Roll a distance. The unit will beepeach time you roll the programmeddi

Page 18 - Programming Mode

Setting a Constant Value (+K)This key is used to add a pre-pro-grammed value to the displayed mea-sured value. If the value is not “live,” then pressi

Page 19 - Setting Custom Scales

3) Press [M+] to increment the dis-tance. When you have reached thecorrect number, press [Scale] to ad-vance to the next digit. Press[Mode] to move b

Page 20 - 20 – Scale Master

Finding Area and VolumeThe Scale Master II can calculate areaand volume once you have your valuesset for length, width, and (for volumecalculation onl

Page 21 - Setting a Custom Scale

2) Roll the second dimension andpress [Width]. This value is storedas the width and the main displaywill reset to zero.3) Press [Sq/Cu] to calculate t

Page 22 - Using the Custom Scale/Ruler

b. To Enter and Store a Height:i. If you are entering a height(instead of rolling), press [Set][SQ/CU].ii. If you do not want to changethe unit of mea

Page 23 - Setting an Auto-Count Value

IntroductionThe Scale MasterII Multi-Scale DigitalPlan Measure has been specificallydesigned to simplify take-offs fromarchitectural and engineering d

Page 24 - [Count]

Other Area/Volume Function Keystrokes[Rcl] [Length]Displays the value stored in theLength register.[Rcl] [Width] Displays the value stored in theWidth

Page 25 - Setting a Constant Value (+K)

Connecting to a PC (optional)The Scale Master II has a built-in com-puter interface connection so that youcan use it with estimating and spread-sheet

Page 26 - 26 – Scale Master

Basic Functions PCYou can send a value using the [Set]key, then store it as Length, Width,Height, or in the memory, as you nor-mally would. Remember,

Page 27 - Finding Area and Volume

Auto-Count Function PC[Rcl] [Set] [Count]Enters Auto-Count programmingmode. The next press of [Set] exitsAuto-Count mode.[Reset] and [Count] simultane

Page 28 - Finding Volume

Error/Auto-Range FunctionError Message – If you make an incor-rect entry (such as trying to add di-mensioned and non-dimensionedvalues), the Scale Ma

Page 29 - [Sq/Cu]. The

Battery/Automatic Shut-OffThe Scale Master II is powered by two3-Volt CR-2430 Lithium batteries (6volts total). To conserve battery power,the unit wil

Page 30 - 30 – Scale Master

Register Values/SettingsPermanent Values/SettingsThe following registers/settings will remain in permanent storage, onlychanging:1) when the settings

Page 31 - Connecting to a PC (optional)

Semi-Permanent Values/SettingsThe following registers/settings arecleared when the Scale Master II is powered down:Register Default DefaultSetting Imp

Page 32 - Memory Functions PC

SpecificationsPower Source:Two 3-Volt CR-2430 lithium batteries.Approximately 400 hours normal use.Display Method:LCD with zero suppression, commas an

Page 33 - Not in Custom Scale Mode

Repair and ReturnWarranty, Repair and Return InformationReturn Guidelines:1.Please read the Warranty in thisUser's Guide to determine if yourCalc

Page 34 - APPENDIX

Key Definitions[Off/On] – Power On/Off switchTurn power On or Off. Turningpower Off clears the display and allvalues previously stored in Mem-ory. Tur

Page 35 - Full Reset/All Clear

Limited WarrantyCalculated Industries, Inc. (“CII”) warrants thisproduct against defects in materials and workman-ship for a period of one (1) year fr

Page 36 - Register Values/Settings

Repair Service — Outside the USANot all countries have CII Authorized ServiceProviders or the same warranty and service policies.To obtain warranty or

Page 37 - Setting Imperial Metric

FCC Class BThis equipment has been certified to comply withthe limits for a Class B computing device, pursuant toSubpart J of Part 15 of FCC rules.Leg

Page 38 - 182mm x 41mm x 15mm

How To Reach Calculated IndustriesUser’s Guide – 43MailCalculated Industries, Inc.4840 Hytech DriveCarson City, NV 89706 U.S.A.Phone1 (775) 885–4900Fa

Page 39 - Repair and Return

Designed in the United States of America Printed in ChinaUG6130E-E7/05

Page 40 - Limited Warranty

[Sub] is pressed simultaneously with[Count], [+K] or [M+], the unit willsubtract the appropriate value.[Count] – Count keyUsed to increase the Count v

Page 41 - Disclaimer

When in programming mode, thiskey moves the cursor back to theprevious item programmed.[Scale] – Scale key Used to cycle through the variousscales wit

Page 42 - LL RIGHTS RESERVED

[Sq/Cu] – Area/Volume key Used to set or view height andcalculate area and volume: 1) The first press of this key calcu-lates and displays the area us

Page 43 - User’s Guide – 43

Adjusting the WheelThe Celcon®polymer wheel can be ad-justed for each user’s preference. Toadjust the wheel, take a small, flat-headjeweler’s screwdri

Page 44 - United States of America

Imperial/Metric ModesThe Scale Master II is set up to useImperial (English) dimensionalunits by default. The Scale Master IIcan be set up to use Metri