Calculated Industries Scale Master Pro XE Specifications

Browse online or download Specifications for Distance meters Calculated Industries Scale Master Pro XE. Calculated Industries Scale Master Pro XE User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 2 - SCALE MASTER

1) Area2) Perimeter3) Volume (if Height is entered)4) Wall Area (if Height is entered)5) Stored Height (if Height is entered)6) Stored Length7)

Page 3 - TABLE OF CONTENTS

Function Keys[M+] – Memory Plus Adds the displayed value to the accumulative value.[RCL] [M+] – Memory Recall Displays the value stored in accumulat

Page 4 - Appendix

[RCL] [SET] [COUNT] – Auto-Count Recall Displays the stored Auto-Count value.[XPC] – PC Send When connected to a PC, sends the value from the main d

Page 5 - GETTING STARTED

Rotate to Adjust WheelAdjusting the WheelThe Celcon® polymer wheel can be adjusted for each user’s preference. To adjust the wheel, take a small, flat

Page 6

PreferencesPreferences allow customization of how the Scale Master Pro XE functions during certain operations. The following preferences are available

Page 7 - Setup Keys

(cont’d)PC Terminate (End PC) – Determines where the “cursor” moves after a value is sent to the PC. The settings represent the key being pressed on t

Page 8

Setting Preferences:1) Press [SET] [MODE] to access the preferences.2) Press the [M+] (S) key to move up or the [RCL] (T) key to move down through the

Page 9 - Measuring Keys

Built-In ScalesImperial (Standard) UnitsArchitect Engineer-I Engineer-II MapARCH ENGI ENGII MAP1 foot= 1 inch= 1 inch= 1 inch=1/4” 10.0’ 300.0’ 1.

Page 10

Metric UnitsArchitect Engineer-I Engineer-II MapARCH ENGI ENGII MAP1:50 1:100.0 1:1,000 1:100k1:75 1:125.0 1:1,250 1:125k1:1 1:150.0 1:1,500 1:200

Page 11 - Function Keys

Changing ModesRepeated presses of the [MODE] key will scroll through the list of available modes. Holding [SUB] when pressing [MODE] will scroll bac

Page 12

SCALE MASTER® PRO XEIntroductionThe Scale Master Pro XE Multi-Scale Digital Plan Measure has been specifically designed to simplify takeoffs from arc

Page 13 - Adjusting the Wheel

OperationUser’s Guide – 16

Page 14 - Preferences

Rolling a MeasurementTo take a measurement with the Scale Master Pro XE:1) Turn the unit on. If the display does not show zero (0), press the [ON/CL

Page 15 - 11 – Scale Master

Using the Memory FunctionThe Memory function allows you to add rolled or counted values. However, you cannot add dimensioned (rolled) and non-dimensio

Page 16 - Imperial/Metric Modes

Additional Memory Functions[SET] [M+]Subtracts the value in the main display from the value stored in Memory.[RCL] [M+]Displays the total accumulated

Page 17 - Built-In Scales

Programming ModeThe Scale Master Pro XE allows you to pre-set frequently used values, including: ● Custom Scales (5 Imp/5 Met)● Auto-Count distance●

Page 18 - Metric Units

Setting Custom ScalesYou can store ten Custom Scales: five in Imperial Mode and five in Metric Mode. You can set a custom scale two ways: by “rolling

Page 19 - Changing Modes

6) Press [M+] (S) to increase or [RCL] (T) to decrease the selected digit. Press the [W/LxW] (X) key to move to the next digit to the right or the [L]

Page 20 - Operation

(cont’d)4) To change the units of measurement, press [UNITS] until your desired units appear. Press the [W/LxW] (X) or the [L] (W) key to begin sett

Page 21 - Rolling a Measurement

Setting an Auto-CountThe Scale Master Pro XE has an Auto-Count function that allows you to count how many times you’ve rolled a certain distance. You

Page 22 - Using the Memory Function

(cont’d)4) Once the desired value has been entered, press [SET] to save changes and put the unit into Auto-Count mode.5) Roll a distance. The unit w

Page 23 - Using Ruler Mode

TABLE OF CONTENTSGetting StartedKey Definitions ...1Operation Keys ...

Page 24 - Programming Mode

2) To change the units of measurement, press [UNITS] until your desired units appear. Press the [W/LxW] (X) or the [L] (W) key to begin setting the

Page 25 - Setting Custom Scales

Setting a HeightThe height function is used to enter a height value for finding volume.To set a Height:1) Press [SET] [L] to access the height functio

Page 26 - Entering a Custom Scale

Finding Area 1) Roll the first side and press the [L] key to store as Length.2) Roll the second side and press [W/LxW] to store as Width. The main

Page 27 - (W) key to

Additional Area/Volume Functions[RCL] [L]Displays the value stored in the Length register.[RCL] [W/LxW]Displays the value stored in the Width register

Page 28 - Setting an Auto-Count

APPENDIXError/Auto-Range FunctionError Message – If you make an incorrect entry (such as trying to add dimensioned and non-dimensioned values togeth

Page 29 - Setting a Constant (+K)

Battery/Automatic Shut-OffThe Scale Master Pro XE is powered by two 3-Volt CR-2032 Lithium batteries (6 volts total). To conserve battery power, the u

Page 30 - Additional Constant Functions

Default SettingsThe following are the factory defaults of the Scale Master Pro XE: Default DefaultSettings Imperial MetricMode ARCH ARCHScale 1/4&

Page 31 - Finding Area and Volume

SpecificationsPower Source:Two 3-Volt CR-2032 lithium batteries.Approximately 400 hours normal use.Display Method:LCD with commas, annunciators and ze

Page 32 - Finding Volume

Repair and ReturnRepair and Return InformationReturn Guidelines:1. Please read the Warranty in this User's Guide to determine if your Calculate

Page 33 - Connecting to a PC (optional)

WarrantyWarranty Repair Service — USACalculated Industries (“CI”) warrants this product against defects in materials and workmanship for a period of o

Page 34 - APPENDIX

AppendixError/Auto-Range Function ... 30Interference ... 30Battery/Automatic Shut

Page 35 - Battery Replacement

Repair Service — Outside the USATo obtain warranty or non-warranty repair service for goods purchased outside the U.S., contact the dealer through whi

Page 36 - Default Settings

FCC Class BNote: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rule

Page 37 - Specifications

User’s Guide – 38MailCalculated Industries, Inc.4840 Hytech DriveCarson City, NV 89706 U.S.A.Phone(775) 885–4900Fax(775) 885–4949E-mailtechsup@calcula

Page 38 - Repair and Return

Software copyrighted and licensed to Calculated Industries by Scale Master Technologies, LLC, 2009. User’s Guide copyrighted by Calculated Industrie

Page 39 - Warranty

1 – Scale Master® Pro XE GETTING STARTEDKey DefinitionsOperation Keys[ON/CLEAR] – On/Clear Turns power on. Press once to clear the display. This wil

Page 40 - Disclaimer

[RESET] – Hardware Reset If your Scale Master Pro XE should ever “lock up,” use a paperclip or similar size object to press the RESET hole. Clears al

Page 41 - Looking for New Ideas

[LOCK] – Lock Switch The Lock Switch is located on the side of the unit. When the lock is activated, a lock symbol will be displayed in the LCD. Whi

Page 42 - Contact Us

[SUB] + [SCALE] – Scrolls Back Scales Holding [SUB] and repeated presses of [SCALE] will scroll backward through the available scales.[UNITS] – Unit

Page 43

[T] ([RCL]) – Down Arrow Decreases the number when setting values for custom scales, auto-count, constant, and height. Will scroll down through the

Comments to this Manuals

No comments