1) Area2) Perimeter3) Volume (if Height is entered)4) Wall Area (if Height is entered)5) Stored Height (if Height is entered)6) Stored Length7)
Function Keys[M+] – Memory Plus Adds the displayed value to the accumulative value.[RCL] [M+] – Memory Recall Displays the value stored in accumulat
[RCL] [SET] [COUNT] – Auto-Count Recall Displays the stored Auto-Count value.[XPC] – PC Send When connected to a PC, sends the value from the main d
Rotate to Adjust WheelAdjusting the WheelThe Celcon® polymer wheel can be adjusted for each user’s preference. To adjust the wheel, take a small, flat
PreferencesPreferences allow customization of how the Scale Master Pro XE functions during certain operations. The following preferences are available
(cont’d)PC Terminate (End PC) – Determines where the “cursor” moves after a value is sent to the PC. The settings represent the key being pressed on t
Setting Preferences:1) Press [SET] [MODE] to access the preferences.2) Press the [M+] (S) key to move up or the [RCL] (T) key to move down through the
Built-In ScalesImperial (Standard) UnitsArchitect Engineer-I Engineer-II MapARCH ENGI ENGII MAP1 foot= 1 inch= 1 inch= 1 inch=1/4” 10.0’ 300.0’ 1.
Metric UnitsArchitect Engineer-I Engineer-II MapARCH ENGI ENGII MAP1:50 1:100.0 1:1,000 1:100k1:75 1:125.0 1:1,250 1:125k1:1 1:150.0 1:1,500 1:200
Changing ModesRepeated presses of the [MODE] key will scroll through the list of available modes. Holding [SUB] when pressing [MODE] will scroll bac
SCALE MASTER® PRO XEIntroductionThe Scale Master Pro XE Multi-Scale Digital Plan Measure has been specifically designed to simplify takeoffs from arc
OperationUser’s Guide – 16
Rolling a MeasurementTo take a measurement with the Scale Master Pro XE:1) Turn the unit on. If the display does not show zero (0), press the [ON/CL
Using the Memory FunctionThe Memory function allows you to add rolled or counted values. However, you cannot add dimensioned (rolled) and non-dimensio
Additional Memory Functions[SET] [M+]Subtracts the value in the main display from the value stored in Memory.[RCL] [M+]Displays the total accumulated
Programming ModeThe Scale Master Pro XE allows you to pre-set frequently used values, including: ● Custom Scales (5 Imp/5 Met)● Auto-Count distance●
Setting Custom ScalesYou can store ten Custom Scales: five in Imperial Mode and five in Metric Mode. You can set a custom scale two ways: by “rolling
6) Press [M+] (S) to increase or [RCL] (T) to decrease the selected digit. Press the [W/LxW] (X) key to move to the next digit to the right or the [L]
(cont’d)4) To change the units of measurement, press [UNITS] until your desired units appear. Press the [W/LxW] (X) or the [L] (W) key to begin sett
Setting an Auto-CountThe Scale Master Pro XE has an Auto-Count function that allows you to count how many times you’ve rolled a certain distance. You
(cont’d)4) Once the desired value has been entered, press [SET] to save changes and put the unit into Auto-Count mode.5) Roll a distance. The unit w
TABLE OF CONTENTSGetting StartedKey Definitions ...1Operation Keys ...
2) To change the units of measurement, press [UNITS] until your desired units appear. Press the [W/LxW] (X) or the [L] (W) key to begin setting the
Setting a HeightThe height function is used to enter a height value for finding volume.To set a Height:1) Press [SET] [L] to access the height functio
Finding Area 1) Roll the first side and press the [L] key to store as Length.2) Roll the second side and press [W/LxW] to store as Width. The main
Additional Area/Volume Functions[RCL] [L]Displays the value stored in the Length register.[RCL] [W/LxW]Displays the value stored in the Width register
APPENDIXError/Auto-Range FunctionError Message – If you make an incorrect entry (such as trying to add dimensioned and non-dimensioned values togeth
Battery/Automatic Shut-OffThe Scale Master Pro XE is powered by two 3-Volt CR-2032 Lithium batteries (6 volts total). To conserve battery power, the u
Default SettingsThe following are the factory defaults of the Scale Master Pro XE: Default DefaultSettings Imperial MetricMode ARCH ARCHScale 1/4&
SpecificationsPower Source:Two 3-Volt CR-2032 lithium batteries.Approximately 400 hours normal use.Display Method:LCD with commas, annunciators and ze
Repair and ReturnRepair and Return InformationReturn Guidelines:1. Please read the Warranty in this User's Guide to determine if your Calculate
WarrantyWarranty Repair Service — USACalculated Industries (“CI”) warrants this product against defects in materials and workmanship for a period of o
AppendixError/Auto-Range Function ... 30Interference ... 30Battery/Automatic Shut
Repair Service — Outside the USATo obtain warranty or non-warranty repair service for goods purchased outside the U.S., contact the dealer through whi
FCC Class BNote: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rule
User’s Guide – 38MailCalculated Industries, Inc.4840 Hytech DriveCarson City, NV 89706 U.S.A.Phone(775) 885–4900Fax(775) 885–4949E-mailtechsup@calcula
Software copyrighted and licensed to Calculated Industries by Scale Master Technologies, LLC, 2009. User’s Guide copyrighted by Calculated Industrie
1 – Scale Master® Pro XE GETTING STARTEDKey DefinitionsOperation Keys[ON/CLEAR] – On/Clear Turns power on. Press once to clear the display. This wil
[RESET] – Hardware Reset If your Scale Master Pro XE should ever “lock up,” use a paperclip or similar size object to press the RESET hole. Clears al
[LOCK] – Lock Switch The Lock Switch is located on the side of the unit. When the lock is activated, a lock symbol will be displayed in the LCD. Whi
[SUB] + [SCALE] – Scrolls Back Scales Holding [SUB] and repeated presses of [SCALE] will scroll backward through the available scales.[UNITS] – Unit
[T] ([RCL]) – Down Arrow Decreases the number when setting values for custom scales, auto-count, constant, and height. Will scroll down through the